TECHNOACOUSTIC - 1200 * 600 * 50 mm (5.76 sq / m)
- category: ქვაბამბა | თბოიზოლაცია / Sound insulation
TECHNOACOUSTIC is a nonflammable, water-repellent thermal and sound insulation slabs made of mineral wool based on lowphenolic-bound basalt rocks. The... See more
TECHNOACOUSTIC is a nonflammable, water-repellent thermal and sound insulation slabs made of mineral wool based on lowphenolic-bound basalt rocks. The particular position of its fibers provide high sound-absorbing properties. Acoustic mineral wool has high physical and mechanical parameters providing reliable performance of the product in vertical structures.
See less
|
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
|
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,035 |
State All-Union standard 7076-99, State All-Union standard 31925-2011 (EN 12667:2001), State All-Union standard31924-2011 (EN 12939:2000) |
|
Thermal conductivity, λD |
W/m·°K |
Not above |
0,036 |
State All-Union standard 32314-2011 (EN 13162:2008) |
|
Thermal conductivity, λА |
W/m·°K |
Not above |
0,038 |
State All-Union standard 7076-99, СП 23-101-2004 |
|
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, СП 23-101-2004 |
|
Compressive strength at 10 % of deformation |
kPa |
Not above |
0,5 |
State All-Union standard EN 826-2011 |
|
Organic matter contents |
% |
Not above |
2,5 |
State All-Union standard 17177-94 |
|
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standardEN 1609-2011 |
|
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
|
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
|
Плотность |
kg/m3 |
- |
41 (±4) |
State All-Union standard 17177-94 |
|
Parameter name |
Measurement unit |
Criteria |
Value |
|
length |
mm |
1200 (1000)* |
State All-Union standard EN 822-2011 |
|
Width |
mm |
50; 75; 100 |
State All-Union standard EN 822-2011 |
|
Thickness |
mm |
20-50* |
State All-Union standard EN 823-2011 |
|
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2011 (EN 13162:2008) |
- diminishes five-fold airborne noise level when used within the system “TH-Stena Acoustic” with 100 mm thick TECHNOACOUSTIC slabs.
- doesn’t shrink
- guarantees safety and environmental performance
- Slabs are used in industrial and civil construction as:
- a thermal and sound insulation layer not being under load: light-weight covering surfaces, partition walls, floors, crawl space slabs, attics and lofts, garret flooring;
- a sound insulation layer in suspended ceilings.
- Storage: Slabs must be stored into containers or stacked on the pallets separately by trade mark and size. Polyethylene heat-shrink film is used for packaging. The material must be protected from atmospheric precipitation during whole period of storage.
- Transportation: Transportation and storage of the slabs must be in compliance with State All-Union standard 25880-83. The slabs are unloaded at storage at least a day before delivering to a customer.
Products offered
delivery
- When purchasing products for up to 80 GEL, the delivery price is 20 GEL;
- When purchasing products in the amount of 80 to 700 GEL, the delivery price is determined on the basis of: 1 km - 2.80 GEL;
- When purchasing products worth more than GEL 700, delivery is free (Tbilisi);
*At this moment delivery service outside the city is not available."
Delivery time:
- Tbilisi
Delivery time: 3-5 working days
Note: Delivery is carried out only to the address, without unloading from the car and delivery to the apartment.
Product comparison
TECHNOACOUSTIC - 1200 * 600 * 50 mm (5.76 sq / m)
choose a product
- Rock wool Terrava 70kg/m3 x 100mm 600x1200
- Stone wool - SW Floating Floor Board 110 110 kg/m3/600x1200x30 mm (5.76m2)
- Rock wool TERRAWOOL 50mm 600x1200(130kg/m3) 2.88 m2
- Stone wool1200 * 600 * 50 mm (4.32 sq / m)
- ISOVER Vent Optimal
- Rock wool TERRAWOOL TW7050 with BLACK GLASS FIBER 50X600X1200 (70 kg/m3)
- stone wool 1200*600*50 მმ (5,76 m2) - 35 kg/m3
- stone wool 1200*600*50 მმ (4.32 sq/m2 )
- ქვაბამბა BONUSWOOL PREMIUM F FACADE 1200*600*100 120 kg/m3 (1,44 m2)
- ქვაბამბა WOOLMAX STONE WOOL BOARD 120*60*5 100კგ/მ3 (2.88მ2)
- Stone wool - Ravatherm 120 kg/m3 50x600x1200 mm (2.88 m2)
- ქვაბამბა BONUS WOOL ALU 1200*600*50 50kg/m3 (5.76m2)
- Stone wool ISOBOX 800*600*50 15 panels/pack (7.2 m2)
- Stone wool - 1200*600*50 mm (8.64 m2)
- Stone wool - Ravatherm 135 kg/m3 50x600x1200 mm (2.88 m2)
- Membrane FLEX AL SA
- Vibration isolating mount Sonocrepe EP 20
- Sonoplat Standard
- Membrane FLEX SA
- High-component spreader NANO FIX - 1KG
- TechnoSonus Hydro
- TechnoSonus VEM 2 SA
- FLEX membrane
- TechnoSonus VEM 2
- Sonoplat Combi
- TechnoSonus VEM 4
- Soundproofing stone wool TechnoSonus BP Standard
- Soundproofing stone wool TechnoSonus BP Floor
- Acoustic casing SoundPack M
- TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
|
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
|
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,035 |
State All-Union standard 7076-99, State All-Union standard 31925-2011 (EN 12667:2001), State All-Union standard31924-2011 (EN 12939:2000) |
|
Thermal conductivity, λD |
W/m·°K |
Not above |
0,036 |
State All-Union standard 32314-2011 (EN 13162:2008) |
|
Thermal conductivity, λА |
W/m·°K |
Not above |
0,038 |
State All-Union standard 7076-99, СП 23-101-2004 |
|
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, СП 23-101-2004 |
|
Compressive strength at 10 % of deformation |
kPa |
Not above |
0,5 |
State All-Union standard EN 826-2011 |
|
Organic matter contents |
% |
Not above |
2,5 |
State All-Union standard 17177-94 |
|
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standardEN 1609-2011 |
|
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
|
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
|
Плотность |
kg/m3 |
- |
41 (±4) |
State All-Union standard 17177-94 |
|
Parameter name |
Measurement unit |
Criteria |
Value |
|
length |
mm |
1200 (1000)* |
State All-Union standard EN 822-2011 |
|
Width |
mm |
50; 75; 100 |
State All-Union standard EN 822-2011 |
|
Thickness |
mm |
20-50* |
State All-Union standard EN 823-2011 |
|
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2011 (EN 13162:2008) |